HJY、HNY、HJKW、HNKW、HJW、HNW重、超重型18~80減速器的熱功率
環(huán)境條件 |
空氣流速
/m·s-1 |
型號(hào) |
規(guī) 格 |
18C 18D |
20C 20D |
22C 22D |
25C 25D |
28C 28D |
31C 31D |
35C 35D |
40C 40D |
45C 45D |
50C 50D |
56C 56D |
63D |
71D |
80D |
不附加冷卻裝置的熱功率PG/kW |
狹小車間 |
≥0.5 |
HJY |
7 |
8 |
10 |
12 |
15 |
18 |
22 |
27 |
38 |
45 |
56 |
76 |
95 |
110 |
HNY |
9 |
10 |
13 |
16 |
20 |
24 |
29 |
35 |
50 |
56 |
71 |
93 |
114 |
129 |
HJKW |
9 |
11 |
13 |
16 |
21 |
25 |
30 |
38 |
53 |
63 |
78 |
106 |
133 |
154 |
HNKW |
13 |
14 |
18 |
22 |
28 |
33 |
40 |
49 |
70 |
78 |
99 |
130 |
160 |
180 |
HJW |
11 |
13 |
17 |
20 |
24 |
31 |
38 |
46 |
64 |
75 |
90 |
122 |
152 |
180 |
HNW |
14 |
16 |
20 |
25 |
30 |
39 |
47 |
57 |
79 |
93 |
112 |
151 |
189 |
224 |
大、中型
車間 |
≥1.4 |
HJY |
9 |
11 |
13 |
17 |
20 |
25 |
31 |
38 |
53 |
63 |
78 |
106 |
133 |
154 |
HNY |
13 |
14 |
18 |
22 |
28 |
34 |
41 |
49 |
70 |
79 |
99 |
130 |
160 |
181 |
HJKW |
13 |
15 |
18 |
24 |
28 |
35 |
43 |
53 |
74 |
88 |
109 |
148 |
186 |
215 |
HNKW |
18 |
20 |
25 |
31 |
39 |
48 |
57 |
69 |
98 |
110 |
138 |
182 |
224 |
253 |
HJW |
16 |
19 |
24 |
28 |
34 |
43 |
53 |
65 |
90 |
105 |
126 |
171 |
213 |
252 |
HNW |
20 |
23 |
28 |
35 |
42 |
54 |
66 |
80 |
110 |
130 |
157 |
211 |
265 |
314 |
室外 |
≥3.7 |
HJY |
13 |
15 |
18 |
23 |
28 |
34 |
42 |
51 |
72 |
86 |
106 |
144 |
181 |
209 |
HNY |
18 |
19 |
25 |
30 |
37 |
46 |
55 |
66 |
95 |
106 |
135 |
177 |
217 |
245 |
HJKW |
18 |
21 |
25 |
32 |
39 |
48 |
58 |
71 |
100 |
120 |
148 |
201 |
253 |
293 |
HNKW |
25 |
27 |
35 |
42 |
52 |
64 |
77 |
92 |
133 |
148 |
189 |
248 |
304 |
343 |
HJW |
22 |
25 |
32 |
38 |
46 |
59 |
72 |
87 |
122 |
143 |
171 |
232 |
289 |
342 |
HNW |
27 |
31 |
38 |
48 |
57 |
73 |
89 |
108 |
150 |
177 |
213 |
287 |
359 |
425 |
注:1、型號(hào)相同的A型和B型,C型和D型熱功率相近,故表中取同一PG值。
2、HH型和HN型熱功率相同。 |